SCHEDA TECNICA/ TECHNICAL DATASHEET
VALVOLE DI SEQUENZA AD AZIONE DIRETTA
DIRECT ACTING
SEQUENCE VALVES
Valvola utilizzata principalmente per far funzionare
in sequenza due cilindri: al raggiungimento di un
determinato valore di taratura, la valvola si apre e
va ad alimentare un secondo attuatore. La valvola
di ritegno permette il libero passaggio del usso
nella direzione opposta. È indicata in impianti dove
la pressione sull’attuatore secondario sia limitata, in
quanto le pressioni si sommano.
SCHEMA IDRAULICO SCHEMA DI MONTAGGIO
PRESSIONE/PORTATAPERDITE DI CARICO
HYDRAULIC DIAGRAM APPLICATION SCHEME
PRESSURE/FLOWPRESSURE DROPS CURVE
Sequence valve is used to feed 2 cylinders in
sequence: it provides ow to the secondary circuit
when a primary circuit function has been completed
reaching the pressure setting. Return ow is free. It’s
ideal for circuits with low pressure on the secondary
actuator as the pressures add to.
USE AND OPERATION:
Per l’impiego con due attuatori seguire le indicazio-
ni di montaggio illustrate nello schema.
Per altri usi montare la valvola tenendo in consi-
derazione che, al raggiungimento del valore di
pressione impostato, il usso va da V in C, mentre
da C a V è libero.
• Molle per diversi campi di taratura (vedi tabelle)
• Pressioni di taratura speciche (CODICE/T 000
specicando il valore di taratura)
A RICHIESTA
• different setting range (see the table)
• other setting available (CODE/T000 please specify
the desired setting)
TIPO / TYPE
VS2C
Corpo: acciaio zincato
Componenti interni: acciaio temprato termicamente
e retticato
Guarnizioni: BUNA N standard
Tenuta: a cono guidato. Tralamento trascurabile
Body: zinc-plated steel.
Internal parts: hardened and ground steel.
Seals: BUNA N standard
Poppet type: minor leakage
Temperatura olio: 50°C - Viscosità olio: 30 cSt
Oil temperature: 50° C - Oil viscosity: 30 cSt
6.1
MATERIALS AND FEATURES:
APPLICATIONS:
MONTAGGIO:
ON REQUEST
MATERIALI E CARATTERISTICHE:
IMPIEGO:
Δ
Δ
Δ
Δ
P (BAR)
P (BAR)
P (BAR)
P (BAR)
FLOW - Q (l/min) FLOW - Q (l/min) FLOW - Q (l/min) FLOW - Q (l/min)
VS2C 3/8” VS2C 1/2” VS2C 3/4”
C V
For use with 2 actuators, follow the mounting instruc-
tions indicated in the scheme. For different uses, mount
the valve keeping into consideration that, when the
valve reaches the setting pressure, the ow goes from V
towards C, whilst ow is free from C to V.
SCHEDA TECNICA/ TECHNICAL DATASHEET
CODICE
CODE
SIGLA
TYPE
PORTATA MAX
MAX FLOW
Lt. / min
V0640 VS2C 3/8” 35 350
V0660 VS2C 1/2” 70 350
V0665 VS2C 3/4” 110 400
V0640 VS2C 3/8” G 3/8” 74 146 14 7 55 39 31 70 30 1,172
V0660 VS2C 1/2” G 1/2” 80 152 15 7 55 37 33 70 30 1,130
V0665 VS2C 3/4” G 3/4” 100 164 20 10 80 50 50 100 40 2,900
162
REGOLAZIONE - ADJUSTEMENT
CODICE/V • CODE/V Volantino Handknob
CODICE/PP • CODE/PP Predisposizione alla piombatura Arranged for sealing cap
CODICE/P • CODE/PP Piombatura Sealing cap
Campo di taratura
Setting range (bar)
Incremento bar per riga
Pressure increase (bar/turn)
Q= 4l/min
Taratura standard
Standard setting
(bar)
MOLLE - SPRINGS (VS2C 3/8” - 1/2”)
10 - 50* 7 30
20 - 100 12 75
10 - 180 standard 30 90
50 - 250 45 130
80 - 300 50 150
Campo di taratura
Setting range (bar)
Incremento bar per riga
Pressure increase (bar/turn)
Q= 4l/min
Taratura standard
Standard setting
(bar)
MOLLE - SPRINGS (VS2C 3/4”)
20 - 200 40 160
50 - 400 standard 80 180
CODICE
CODE
SIGLA
TYPE
C - V
GAS
L3
mm
L
mm
L4
mm
L2
mm
L6
mm
H
mm
L1
mm
L5
mm
S
mm
PESO/
WEIGHT
Kg
RANGE DI PRESSIONE
PRESSURE RANGE
Bar
6
*Per tarature inferiori a 70 Bar: Q = 12 l/min *For setting less than 70 Bar: Q = 12 l/min